Model:
SL400
|
FEATURES
|
|
Maximum Power
|
400W |
|
Transient Response
|
+5V,+12V outputs return
to within 5% in less than 1ms for 20%
load change. |
|
P. G. Signal
|
100-500ms |
|
Over Voltage Protection
recycle AC to
reset
|
+5V trip point <
+6.5V
+3.3V trip point
< +4.1V
+12V trip point
< +15.6
|
|
Overload Protection
|
Latching Protection
+5V @ < 53A
+3.3V @ < 48A
+12V @ < 23A
|
|
Leakage Current
|
<3.5mA @ 240VAC
|
|
OUTPUT
|
|
|
+5V
|
-5V
|
+12V |
-12V
|
+3.3V
|
+5V
SB
|
|
Max. Load
|
38A* |
0.5A |
18A |
0.8A |
28A* |
2.0A |
| Min. Load
|
1.5A |
0A |
0.8A |
0A |
0.5A
|
0A |
|
Load Reg.
|
±
5%
|
±
10%
|
±
5%
|
±
10%
|
±
5%
|
±
5%
|
|
Rippe
V(p-p)
|
50mV
|
100mV
|
120mV
|
120mV
|
50mV
|
50mV
|
- * +5V and +3.3V combined output:
240Watts max.
- * +5V, +3.3V and +12V combined output:
380Watts max
|
|
INPUT
|
|
Input Voltage
|
115VAC/230VAC
|
|
Input Frequency Range
|
47Hz to 63Hz
|
|
Input Surge Current
(p-p)
|
<
50A @115VAC
<
80A @230VAC |
|
Input Current
|
10.0A for 115VAC
5.0A for 230VAC
|
|
Hold-up Time
|
<
17ms at Full Load |
|
Efficiency |
>
68%
|
|
EMI/RFI |
FCC Class B
|
|
ENVIRONMENTAL
|
|
Operating Temp.
|
10 ºC to 50 ºC
|
|
Operating Alt.
|
Sea Level-10,000 ft
|
|
Non-Operating
Vibration
|
Operating:
10-300 Hz, 0.5G, 3 axes, 1hr ea. axis
Non-operating:
10-300 Hz, 2.0G, 3 axes, 1hr. ea axis |
|
MTBF |
50,000 hrs. @ 25ºC
|
|
Weight |
5 lbs. |
|
Approvals |
UL,
TUV, CB, FCC CLASS B, NEMKO |
|
|
|
|