Model: PP300V
|
| FEATURES |
| Maximum Power |
300W |
| Transient Response |
+5V,+12V outputs return to within 5% in less than 1ms for 20% load change. |
| P. G. Signal |
100-500ms |
Over Voltage Protection:
Recycle AC to reset |
+5V trip point < +6.9V |
Overload Protection
|
Outputs equipped w/short circuit protection |
| Leakage Current |
< 3.5mA @ 240VAC |
|
| INPUT |
| Input Voltage |
115VAC/230VAC |
| Input Frequency Range |
47Hz to 63Hz |
| Input Surge Current (p-p) |
< 45A @ 115VAC Cold start |
| Input Current |
7.0A for 115VAC
4.0A for 230VAC |
| Hold-up Time |
< 16 ms at Full Load |
| Efficiency |
< 70% |
| EMI/RFI |
FCC Class B |
|
| OUTPUT |
| |
+5V |
-5V |
+12V |
-12V |
| Max. Load |
30A |
1A |
10A |
1A |
| Min. Load |
5A |
0A |
2.5A |
0A |
| Load Reg. |
±5% |
±10% |
±5% |
±10% |
| Ripple V(p-p) |
50mV |
50mV |
120mV |
120mV |
|
| ENVIRONMENTAL |
| Operating Temp. |
0 to 50℃ |
| Operating Alt. |
Sea Level 10,000 ft. |
| Non-Operating Vibration |
5-60Hz, 0.005 inches amplitude 3 axes, 1 hr ea. axis |
| MTBF |
55,000 hrs. @ 25℃ |
| Weight |
5 lbs. |
| Approvals |
UL, CSA, TUV, CE |
|
|