Antec logo  

Model: PP300V

FEATURES

Maximum Power 300W
Transient Response +5V,+12V outputs return to within 5% in less than 1ms for 20% load change.
P. G. Signal 100-500ms
Over Voltage Protection:
Recycle AC to reset
+5V trip point < +6.9V
Overload Protection
Outputs equipped w/short circuit protection
Leakage Current < 3.5mA @ 240VAC
INPUT
Input Voltage 115VAC/230VAC
Input Frequency Range 47Hz to 63Hz
Input Surge Current (p-p) < 45A @ 115VAC Cold start
Input Current 7.0A for 115VAC
4.0A for 230VAC
Hold-up Time < 16 ms at Full Load
Efficiency < 70%
EMI/RFI FCC Class B
OUTPUT
  +5V -5V +12V -12V
Max. Load 30A 1A 10A 1A
Min. Load 5A 0A 2.5A 0A
Load Reg. ±5% ±10% ±5% ±10%
Ripple V(p-p) 50mV 50mV 120mV 120mV
ENVIRONMENTAL
Operating Temp. 0 to 50℃
Operating Alt. Sea Level 10,000 ft.
Non-Operating Vibration 5-60Hz, 0.005 inches amplitude 3 axes,
1 hr ea. axis
MTBF 55,000 hrs. @ 25℃
Weight 5 lbs.
Approvals UL, CSA, TUV, CE