Antec logo  


Model: Phantom350

FEATURES
Switches ATX Logic on-off
Maximum Power 350W

Transient Response

+5V,+12V and 3.3V outputs return to within 5% in less than 1ms for 20% load change.

P. G. Signal

100-500ms

Over Voltage Protection
recycle AC to reset

+5V trip point < +6.2V
+3.3V trip point < +4.1V
+12V trip point < +14.3V

Special Connectors

ATX12V
SATA
PCI Express

Leakage Current

<3.5mA @ 115VAC



DIMENSIONS

Unit Size

5.9"(L) x 6.4"(W) x 3.4"(H)
15cm(L) x 16 cm(W) x 8.6 cm(H)

Net Weight

7.5lbs / 3.4kg



class="specs_b"OUTPUT

+5V +12V1 +12V2 +3.3V -12V +5Vsb

Max. Load

30A

16A

18A

28A

1.0A

2.0A

Min. Load

0.3A

0.4A

0.4A

0.3A

0A

0A

Load Reg.

±5% ±5% ±5% ±5% ±5% ±5%

Rippe
V(p-p)

50

120

120

50

120

50



INPUT

Input Voltage

100Vac to 240Vac +/- 10%

Input Frequency Range

47Hz to 63Hz

Inrush Current

60A @ 115V , 100A @ 230V

Input Current

12A @ 115V, 6A @ 230V

Hold-up Time

20ms at full load

Efficiency

82%(min.) at full loads, 115V/230Vac 60/50Hz

EMI/RFI

FCC Class B



ENVIRONMENTAL

Operating Temp.

0 ºC to 65 ºC

Operating Alt.

Sea Level-10,000 ft

MTBF

80,000 hours at 25’C

Safety Approval

TUV, UL, CUL, CE, CB, FCC