Model: Phantom350
|
FEATURES |
| Switches |
ATX Logic on-off
Additional power rocker switch |
| Maximum Power |
350W |
|
Transient Response
|
+5V,+12V and 3.3V outputs return to within 5% in less than 1ms for 20% load change. |
|
P. G. Signal
|
100-500ms
|
|
Over Voltage Protection
recycle
AC to reset |
+5V trip point
< +6.2V
+3.3V trip
point < +4.1V
+12V trip
point < +14.3V |
|
Special Connectors |
ATX12V
SATA
PCI Express |
|
Leakage Current
|
<3.5mA @ 115VAC
|
| DIMENSIONS
|
|
Unit Size |
5.9"(L) x 6.4"(W) x 3.4"(H)
15cm(L) x 16 cm(W) x 8.6 cm(H) |
|
Net Weight |
7.5lbs / 3.4kg |
|
class="specs_b"OUTPUT
|
|
|
+5V
|
+12V1 |
+12V2 |
+3.3V |
-12V |
+5Vsb |
|
Max. Load |
30A |
16A |
18A |
28A |
1.0A |
2.0A |
|
Min.
Load |
0.3A |
0.4A |
0.4A |
0.3A |
0A |
0A |
|
Load Reg. |
±5% |
±5% |
±5% |
±5% |
±5% |
±5% |
|
Rippe
V(p-p) |
50 |
120 |
120 |
50 |
120 |
50 |
| INPUT |
|
Input Voltage
|
100Vac to 240Vac +/- 10% |
|
Input Frequency
Range |
47Hz to 63Hz
|
|
Inrush Current |
60A @ 115V , 100A @ 230V |
|
Input Current
|
12A @ 115V, 6A @ 230V |
|
Hold-up Time
|
20ms at full load |
|
Efficiency
|
85%(US version) / 82%(EU version
with PFC) at full loads, 115V/230Vac 60/50Hz |
|
EMI/RFI
|
FCC Class B
|
| ENVIRONMENTAL
|
|
Operating Temp.
|
0 ºC to 65 ºC
|
|
Operating Alt.
|
Sea Level-10,000
ft |
|
MTBF |
80,000 hours at 25’C |
|
Safety Approval |
TUV, UL, CUL, CE, CB, FCC |
|
|
|