Test Results for True330

Voltage readings in blue are the numbers recorded from the electronic load machine display. These are the voltage outputs under load conditions.

Total Actual Output in red is the calculated total output power in watts.

LOAD +5V +12V -5V -12V +3.3V +5V SB Calculated Actual Output (W) Total Theoretical Output (W)
A V A V A V A V A V A V
Rated 30.0   17.0   0.5   1.0   28.0   2.0  
10% 3.0 5.01 2.0 12.28 0.5 5.03 1.0 11.92 3.0 3.36 2.0 5.08 74.27 73.40
25% 7.5 4.99 4.5 12.26 0.5 5.05 1.0 11.94 7.0 3.36 2.0 5.06 140.70 139.10
50% 15.0 4.96 8.0 12.22 0.5 5.08 1.0 11.99 14.0 3.30 2.0 5.03 242.95 241.70
100% 30.0 4.91 5.5 12.19 0.5 5.14 1.0 12.05 28.0 3.25 2.0 4.97 329.91 332.90
100% 3.0 4.96 17.0 12.19 0.5 5.10 1.0 12.02 28.0 3.27 2.0 5.06 338.36 335.90
100% 25.0 4.93 10.0 12.20 0.5 5.12 1.0 12.03 20.0 3.27 2.0 4.99 335.22 335.50
110% 3.5 4.96 18.5 12.21 0.5 5.10 1.0 12.00 31.0 3.27 2.0 4.96 369.09 366.30
120% 9.5 4.94 18.5 12.03 0.5 5.12 1.0 12.03 31.0 3.26 2.0 4.98 395.10 396.30

Special Note: Antec without exception does not recommend that users put a load on a power supply larger than the unit is rated for. Antec without exception does not warrant that its power supplies will perform within specification at loads above the rated capacity of the power supply. Antec disclaims all liability for the consequences of using Antec equipment outside of its rated capabilities or not in accord with Antec's recommendations and requirements. Putting a load on an Antec power supply larger than the power supply's rating will void the manufacturer's warranty. You have been warned. The results given above are merely the results for the tested unit, shared purely for interest's sake. If you attempt to recreate this experiment, or otherwise use Antec equipment outside of its rated capabilities, you do so entirely at your own risk.